S6L Network Connections 19
5. Local 16 I/O
Local 16 I/O can be connected to provide I/O at the mix position when using S6L-16C,
or additional mix position I/O with other S6L control surfaces. Local 16 requires two
AVB-192 Network Cards in the E6L engine, and must be connected on the local (con-
sole-to-E6L) ring.
After connecting Local 16s, if any, proceed to
VENUE System Restore for First Time Setup.
6. About I/O Sharing
The VENUE S6L system lets you share the Stage inputs and outputs of connected Stage I/O units between three pairs of E6L engine
and S6L control surface.
If you will be using I/O sharing, follow these guidelines:
• Both systems must be running the same version of VENUE software.
• Make sure systems are not connected for I/O sharing while installing a Software Update or performing a System Restore.
• After verifying connections and software installation, and after confirming that each system is successfully running the same
version of VENUE software, follow the instructions in
About I/O Sharing.
5 Proceed to VENUE System Restore for First Time Setup.
How to Proceed
After connecting all components, proceed to VENUE System Restore for First Time Setup.
Figure 6. Network port connections (A to B) between S6L control surface, E6L engine with 2x AVB-192 cards with a Local 16 I/O, and a
Stage 64 I/O
If multiple Pro Tools systems are present, Avid recommends that you first connect, power on, and configure S6L system devices
before making
Optional Connections for Pro Tools and ECx Ethernet Control.
IN
OUT
NETWORK
MASTER 1
WORD CLOCK
UTIL
EXPANSION
2
3
6
7
8
1
2
3
4
5
OKOK
A
B
AVB-192
ACT SIG ACT SIG
ACT SIG ACT SIG
A
B
AVB-192
ACT SIG ACT SIG
ACT SIG ACT SIG
A
B
AVB-192
ACT SIG ACT SIG
ACT SIG ACT SIG
A
B
AVB-192
ACT SIG ACT SIG
ACT SIG ACT SIG
A
B
MASTER 1
NETWORK
2
ACT
ACT AC TSIG SIG
POWER A
100-240 VAC 50/60Hz
POWER B
100-240 VAC 50/60Hz
ABCD EFGHJKLM
1
2
3
4
5
6
7
8
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
INPUT
SRI-192
1
2
3
4
5
6
7
8
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
INPUT
SRI-192
1
2
3
4
5
6
7
8
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
INPUT
SRI-192
1
2
3
4
5
6
7
8
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
INPUT
SRI-192
1
2
3
4
5
6
7
8
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
INPUT
SRI-192
1
2
3
4
5
6
7
8
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
INPUT
SRI-192
SIG MUTE
MUTE
MUTE
MUTE
MUTE
MUTE
MUTE
MUTE
SIG
SIG
SIG
SIG
SIG
SIG
SIG
OUTPUT
SRO-192
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
INPUT
SRI-192
1
2
3
4
5
6
7
8
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
SIG +48V
INPUT
SRI-192
SIG MUTE
MUTE
MUTE
MUTE
MUTE
MUTE
MUTE
MUTE
SIG
SIG
SIG
SIG
SIG
SIG
SIG
OUTPUT
SRO-192
1
2
3
4
5
6
7
8
SIG MUTE
MUTE
MUTE
MUTE
MUTE
MUTE
MUTE
MUTE
SIG
SIG
SIG
SIG
SIG
SIG
SIG
OUTPUT
SRO-192
1
2
3
4
5
6
7
8
SIG MUTE
MUTE
MUTE
MUTE
MUTE
MUTE
MUTE
MUTE
SIG
SIG
SIG
SIG
SIG
SIG
SIG
OUTPUT
SRO-192
1
2
3
4
5
6
7
8
I B to A J
I B to A J
I A to B J
I A to B J
K A
to
B J
Console ring, primary
Console ring, redundant
Stage I/O ring, primary
Stage I/O ring, redundant