EasyManuals Logo

Balluff BVS HS-P Series User Manual

Balluff BVS HS-P Series
314 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #108 background imageLoading...
Page #108 background image
108
3
Configuration Using Barcodes
Balluff BVS HS-P Family
Industrial Handheld Barcode Readers
Code 39 Check
Character
Transmission
Enable this option to transmit the check character along with Code 39 barcode data.
Code 39 Start/
Stop Character
Transmission
Enable this option to enable/disable transmission of Code 39 start and stop characters.
Code 39 Full
ASCII
Enables/disables the translation of Code 39 characters to Code 39 full-ASCII characters.
Code 39 Check Character Transmission =
Don’t Send
Code 39 Check Character Transmission =
Send
C3CT00(CR
C3CT01(CR
DEFAULT
Code 39 Start/Stop Character Transmission =
Don’t Transmit
Code 39 Start/Stop Character Transmission =
Transmit
DEFAULT
C3SS00(CR
C3SS01(CR
Code 39 Full ASCII = Disable
Code 39 Full ASCII = Enable
DEFAULT
C3FA00(CR)
C3FA01(CR)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Balluff BVS HS-P Series and is the answer not in the manual?

Balluff BVS HS-P Series Specifications

General IconGeneral
BrandBalluff
ModelBVS HS-P Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals