EasyManuals Logo

Balluff BVS HS-P Series User Manual

Balluff BVS HS-P Series
314 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #113 background imageLoading...
Page #113 background image
113
www.balluff.com
3
Configuration Using Barcodes
Balluff BVS HS-P Family
Industrial Handheld Barcode Readers
3.8.13 Code 32 (Ital
Pharmaceutical
Code)
The following options apply to the Code 32 (Italian Pharmaceutical Code) symbology.
Code 32
Enable/Disable
When disabled, the reader will not read Code 32 barcodes.
Code 32
Feature Setting
Exceptions
Code 32 Check
Character
Transmission
Enable this option to transmit the check character along with Code 32 barcode data.
Code 32 = Disable
Code 32 = Enable
DEFAULT
P3EN00(CR
P3EN01(CR
NOTE
The following features are set for Code 32 by using these Code 39 settings:
"Code 39 Quiet Zones" on page 109
"Code 39 Length Control" on page 109
"Trioptic Code" on page 112
Code 32 Check Character Transmission =
Don’t Send
Code 32 Check Character Transmission =
Send
DEFAULT
P3CT00(CR
P3CT01(CR