280
5
Appendix A: Technical Specifications
Balluff BVS HS-P Family
Industrial Handheld Barcode Readers
5.4 Error Codes Upon startup, if the reader sounds a long tone, this means the reader has not passed its auto-
matic Selftest and has entered FRU (Field Replaceable Unit) isolation mode. If the reader is reset,
the sequence will be repeated. Press and release the trigger to hear the FRU indication code.
The following table describes the LED flashes/beep codes associated with an error found.
5.4.1 Base Station
Indications
(Cordless
Models ONLY)
Base Station
Button
Indicators
NUMBER OF LED FLASHES/BEEPS Error CORRECTIVE ACTION
1 Configuration
Contact Helpdesk for assis-
tance
2 Interface PCB
6 Digital PCB
11 Imager
BUTTON PUSH
EVENT
CORDLESS
RED
INDICATOR(**)
GREEN
INDICATOR(**)
Push at power-up force device connection Off
Slow blink
Fast blink
< 5 sec Paging Off Fast blink
5 to 10 sec Unlink (Only Bluetooth) Off Slow blink