56
3
Configuration Using Barcodes
Balluff BVS HS-P Family
Industrial Handheld Barcode Readers
3.5.1 USB-OEM
Device Usage
The USB-OEM protocol allows for the reader to be identified as one of two different types of bar-
code readers. Depending on what other readers you may already have connected to a USB-OEM
POS, you may need to change this setting to enable all devices to communicate.
Options are:
- Table Top reader
- Handheld reader
Interface
Options
This feature provides for an interface-specific control mechanism.
USB-OEM Device Usage = Table Top Reader
USB-OEM Device Usage = Handheld Reader
IBUT00(CR)
IBUT01(CR)
DEFAULT
Obey Reader Configuration Host Commands
Ignore Reader Configuration Host Commands
CIFO101(CR)
IFO102(CR)
DEFAULT