EasyManuals Logo

Banner Q4X User Manual

Banner Q4X
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
Required Overcurrent Protection
WARNING: Electrical connections must be made by
qualified personnel in accordance with local and
national electrical codes and regulations.
Overcurrent protection is required to be provided by end product application
per the supplied table.
Overcurrent protection may be provided with external fusing or via Current
Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to www.bannerengineering.com.
Supply Wiring (AWG) Required Overcurrent Protection (Amps)
20 5.0
22 3.0
24 2.0
26 1.0
28 0.8
30 0.5
Certifications
Industrial
Control
Equipment
3TJJ
Class 2 power
UL Environmental Rating: Type 1
chemical compatibility certified
ECOLAB is a registered trademark of Ecolab USA Inc. All rights reserved.
5.1 Dimensions
All measurements are listed in millimeters [inches], unless noted otherwise.
Figure 21. Threaded Barrel Models
Q4X Stainless Steel Laser Sensor with Dual Discrete Outputs and IO-Link
32 www.bannerengineering.com - Tel: 763.544.3164

Table of Contents

Other manuals for Banner Q4X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Banner Q4X and is the answer not in the manual?

Banner Q4X Specifications

General IconGeneral
Sensing ModeDiffuse
Input Voltage10 V DC to 30 V DC
OutputNPN or PNP
Housing MaterialStainless steel
IP RatingIP67
Connection TypeM12

Related product manuals