5.3 Performance Curves—Flush Mount Models
Minimum Separation Distance Between Target and Background for: Uniform and Non-Uniform Targets
110 mm Models
310 mm Models
Minimum Separation Target to Background (mm)
Dimension Y
Distance to Target (mm)
Dimension X
0
2
4
6
8
10
12
14
16
18
20
22
0 25 50 75 100 125 150 175 200 225 250 275 300 325
Matte targets with uniform
reflectivity: 6% to 90%
Target
Switch Point
Distance
Background
X
Y
Matte targets with a non-uniform
reflectivity: 6% to 90%
Minimum Separation Target to Background (mm)
Dimension Y
Distance to Target (mm)
Dimension X
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
0 25 35 50 75 100 125
Matte targets with a non-uniform
reflectivity: 6% to 90%
Matte targets with uniform
reflectivity: 6% to 90%
Flush Mount Models
110
35
310
610
610 mm Models
Minimum Separation Target to Background (mm)
Dimension Y
Distance to Target (mm)
Dimension X
0
2
4
6
8
10
12
14
16
18
20
22
0 100
35
200 300 400 500 600
Matte targets with uniform
reflectivity: 6% to 90%
Matte targets with a non-uniform
reflectivity: 6% to 90%
Figure 24. Minimum Object Separation Distance (90% to 6% reflectance)
Q4X Stainless Steel Laser Sensor with Dual Discrete Outputs and IO-Link
www.bannerengineering.com - Tel: 763.544.3164 35

Table of Contents

Other manuals for Banner Q4X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Banner Q4X and is the answer not in the manual?

Banner Q4X Specifications

General IconGeneral
Sensing ModeDiffuse
Input Voltage10 V DC to 30 V DC
OutputNPN or PNP
Housing MaterialStainless steel
IP RatingIP67
Connection TypeM12