EasyManuals Logo

Basler A102f User Manual

Basler A102f
170 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #76 background imageLoading...
Page #76 background image
Configuring the Camera
4-14 BASLER A102
f
DRAFT
Register Name: Trigger Inquiry
Offset from Base Address: 0x530
Field Bit Description A102f
Value
A102fc
Value
Presence Inq
0 Trigger control feature is present 1 1
Abs Control Inq 1 Trigger can be set with an absolute value 0 0
--- 2 ... 3 Reserved --- ---
Read Out Inq 4 The trigger value can be read 1 1
On/Off Inq 5 Trigger control can be switched on/off 1 1
Polarity Inq 6 The trigger input polarity can be changed 1 1
Value Read 7 The raw trigger input can be read 1 1
Trigger Source 0 Inq 8 Trigger source 0 is present (ID = 0) 1 1
Trigger Source 1 Inq 9 Trigger source 1 is present (ID = 1) 1 1
Trigger Source 2 Inq 10 Trigger source 2 is present (ID = 2) 1 1
Trigger Source 3 Inq 11 Trigger source 3 is present (ID = 3) 1 1
--- 12 ... 14 Reserved --- ---
Software Trigger Inq 15 Software trigger is present (ID = 7) 1 1
Trigger Mode 0 Inq 16 Trigger mode 0 is present 1 1
Trigger Mode 1 Inq 17 Trigger mode 1 is present 1 1
Trigger Mode 2 Inq 18 Trigger mode 2 is present 0 0
Trigger Mode 3 Inq 19 Trigger mode 3 is present 0 0
Trigger Mode 4 Inq
20 Trigger mode 4 is present 0 0
Trigger Mode 5 Inq 21 Trigger mode 5 is present 0 0
--- 22 ... 29 Reserved --- ---
Trigger Mode 14 Inq 30 Trigger mode 14 is present
(Vendor unique trigger mode 0)
0 0
Trigger Mode 15 Inq
31 Trigger mode 15 is present
(Vendor unique trigger mode 1)
0 0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Basler A102f and is the answer not in the manual?

Basler A102f Specifications

General IconGeneral
BrandBasler
ModelA102f
CategoryDigital Camera
LanguageEnglish

Related product manuals