Configuring the Camera
4-14 BASLER A102
f
DRAFT
Register Name: Trigger Inquiry
Offset from Base Address: 0x530
Field Bit Description A102f
Value
A102fc
Value
Presence Inq
0 Trigger control feature is present 1 1
Abs Control Inq 1 Trigger can be set with an absolute value 0 0
--- 2 ... 3 Reserved --- ---
Read Out Inq 4 The trigger value can be read 1 1
On/Off Inq 5 Trigger control can be switched on/off 1 1
Polarity Inq 6 The trigger input polarity can be changed 1 1
Value Read 7 The raw trigger input can be read 1 1
Trigger Source 0 Inq 8 Trigger source 0 is present (ID = 0) 1 1
Trigger Source 1 Inq 9 Trigger source 1 is present (ID = 1) 1 1
Trigger Source 2 Inq 10 Trigger source 2 is present (ID = 2) 1 1
Trigger Source 3 Inq 11 Trigger source 3 is present (ID = 3) 1 1
--- 12 ... 14 Reserved --- ---
Software Trigger Inq 15 Software trigger is present (ID = 7) 1 1
Trigger Mode 0 Inq 16 Trigger mode 0 is present 1 1
Trigger Mode 1 Inq 17 Trigger mode 1 is present 1 1
Trigger Mode 2 Inq 18 Trigger mode 2 is present 0 0
Trigger Mode 3 Inq 19 Trigger mode 3 is present 0 0
Trigger Mode 4 Inq
20 Trigger mode 4 is present 0 0
Trigger Mode 5 Inq 21 Trigger mode 5 is present 0 0
--- 22 ... 29 Reserved --- ---
Trigger Mode 14 Inq 30 Trigger mode 14 is present
(Vendor unique trigger mode 0)
0 0
Trigger Mode 15 Inq
31 Trigger mode 15 is present
(Vendor unique trigger mode 1)
0 0