Mechanical Considerations
5-4 Basler A500k Series
PRELIMINARY
5.3 Positioning Accuracy of the Sensor Chip
Positioning accuracy of the sensor chip in the horizontal direction (that is, along the line of pixels)
is ± 0.4 mm and in the vertical direction is ± 0.4 mm. Rotational positioning accuracy is as shown
in Figure 5-3. Reference position is the center of the camera housing.
The maximum rotational mis-positioning and the maximum horizontal/vertical mis-positioning
cannot occur at the same time since the translatory and rotational positioning tolerance depend
on each other.
Figure 5-3: Rotational Positioning Accuracy
Not to scale
Not to
scale