Basic Operation and Features
3-20 Basler A500k Series
PRELIMINARY
3.3.3.4 ExSync, Programmable Mode with Synchronous Timing 2
Figure 3-18: ExSync, Programmable Mode - Exposure Start and Stop with Frame Valid High
If the exposure starts and ends while Frame Valid is high (see Table for values n to z):
The actual start of exposure can be x µs later than the rise of the ExSync signal.
Actual length of exposure time = n - y µs...n + z µs
The actual length of exposure time can only occur in multiples of w µs.
A504k/kc A501k/kc
n exposure set by ExSync
x
1.7 µs to 3.7 µs 6.9 µs to 20.2 µs
y
1 µs 7.4 µs
z
2 µs 20.7 µs
w
2 µs 13.2 µs
Frame
Valid
FlashOut
Line
Valid
ExSync
ExSync Period
Exposure Time
(Timer 1)
41.2 µs (A501k/kc)
6.9 µs...20.2 µs (A501k/kc)
300 ns (A501k/kc)
5.1µs ... 6.6 µs (A504k/kc)
44 ns (A504k/kc)
1.7 µs...3.7 µs (A504k/kc)