Configuring the Camera
Basler A500k Series 4-1
PRELIMINARY
4 Configuring the Camera
A500k cameras come factory-set so that they will work properly for most applications with minor
changes to the camera configuration. For normal operation, the following parameters are usually
configured by the user:
Exposure time control mode
Exposure time (for ExSync programmable mode or free-run programmable mode)
Long Exposure Compensation (
A504k/kc only)
To customize operation for your particular application, the following parameters can also be
configured:
•Gain
•Offset
Digital Shift
Area of Interest
Dynamic Area of Interest
Area of Interest Stamp
Flash Trigger
The camera is programmable via the serial port. Two methods can be used to change the
camera’s settings. The first and easier approach is to change the settings using the Camera
Configuration Tool Plus (CCT+). See Section 4.1 for complete instructions on using the
configuration tool. You can also change the settings directly from your application using binary
commands. Section 4.2 lists the commands and provides instructions for their use.