EasyManua.ls Logo

Baumer IDC200 - Page 23

Default Icon
69 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Baumer Description | 3
V1.0 | IDC200 Operating Manual 23
Module: Parameter
Parameter - default value for first code or parameter telegram being read according to user defi-
nition. Multiple modules permitted (8, 16, 32, 64, 128, 240 bytes).
n
permitted in slot 3
Group DataItem Format Direction Description Comment
Parameter Parameters at different amounts of bytes (8, 16, 32, 64, 128, 240)
Length UINT16 PLC → Sen-
sor
Effective length of user
data in Data.
Data Octet[X] PLC → Sen-
sor
Parameter - default
value for first code or
parameter telegram be-
ing read according to
user definition / (→
GUI).
several modules
possible (8, 16, 32,
64, 128, 240 bytes)
HS OUT Handshake output data (data as above).

Table of Contents

Related product manuals