Error correction
EL72x1-901x238 Version: 1.9
Text ID Type Place Text Message Additional comment
0x4000 Warning Warning: 0x%X, 0x%X,
0x%X
General warning; parameters depend on event. See
device documentation for interpretation.
0x4001 Warning System Warning: 0x%X, 0x%X,
0x%X
0x4002 Warning System %s: %s Connection
Open (IN:%d OUT:%d
API:%dms) from %d.%d.
%d.%d successful
0x4003 Warning System %s: %s Connection
Close (IN:%d OUT:%d)
from %d.%d.%d.%d suc-
cessful
0x4004 Warning System %s: %s Connection (IN:
%d OUT:%d) with %d.
%d.%d.%d timed out
0x4005 Warning System %s: %s Connection
Open (IN:%d OUT:%d)
from %d.%d.%d.%d de-
nied (Error: %u)
0x4006 Warning System %s: %s Connection
Open (IN:%d OUT:%d)
from %d.%d.%d.%d de-
nied (Input Data Size ex-
pected: %d Byte(s) re-
ceived: %d Byte(s))
0x4007 Warning System %s: %s Connection
Open (IN:%d OUT:%d)
from %d.%d.%d.%d de-
nied (Output Data Size
expected: %d Byte(s) re-
ceived: %d Byte(s))
0x4008 Warning System %s: %s Connection
Open (IN:%d OUT:%d)
from %d.%d.%d.%d de-
nied (RPI:%dms not sup-
ported -> API:%dms)
0x4101 Warning General Terminal-Overtempera-
ture
Overtemperature. The internal temperature of the ter-
minal exceeds the parameterized warning threshold
0x4102 Warning General Discrepancy in the PDO-
Configuration
The selected PDOs do not match the set operating
mode.
Sample: Drive operates in velocity mode, but the ve-
locity PDO is but not mapped in the PDOs.
0x417F Warning General Warning: 0x%X, 0x%X,
0x%X
0x428D Warning General Challenge is not Ran-
dom
0x4300 Warning Encoder Subincrements deacti-
vated: %d, %d
Sub-increments deactivated (despite activated configu-
ration)
0x4301 Warning Encoder Encoder-Warning General encoder error
0x4400 Warning Drive Drive is not calibrated:
%d, %d
Drive is not calibrated
0x4401 Warning Drive Starttype not supported:
0x%X, %d
Start type is not supported
0x4402 Warning Drive Command rejected: %d,
%d
Command rejected
0x4405 Warning Drive Invalid modulo subtype:
%d, %d
Modulo sub-type invalid
0x4410 Warning Drive Target overrun: %d, %d Target position exceeded
0x4411 Warning Drive DC-Link undervoltage
(Warning)
The DC link voltage of the terminal is lower than the
parameterized minimum voltage. Activation of the out-
put stage is prevented
0x4412 Warning Drive DC-Link overvoltage
(Warning)
The DC link voltage of the terminal is higher than the
parameterized maximum voltage. Activation of the out-
put stage is prevented
0x4413 Warning Drive I2T-Model Amplifier
overload (Warning)
- The amplifier is being operated outside the specifica-
tion
- The I2T-model of the amplifier is incorrectly parame-
terized

Table of Contents