Section 3 - Programming from PC
Figure 3.9- Partitions Page
Partitions Page
This section describes the Partitions page (see Figure 3.9).
Partitions Table
No. - This column shows the Partition ID number that will be used instead of
the Partition label (Description), in some parts of the application.
Description - This field is for the Partition label (maximum 16 characters). The
Application will use the label as the Partition ID.
Exit Time - This parameter determines the Exit delay time (expressed in min-
utes). Violation of ‘Delayed’ Zones during the Exit time will not provoke Alarms.
The Exit Time will start when the Partition arms, and will be signalled by:
Activation of the Partition OC Outputs (programmed with the ‘Exit Time’
signal);
A series of single beeps (emitted at one-second intervals) on all the Parti-
tion Keypads (Mute keypads will not emit this signal);
A series of double beeps (emitted at one-second intervals) on all the Par-
tition PROXI Readers, the ‘Chime on PROXI Reader’ option must be ena-
bled otherwise, the PROXI Readers will not emit this signal (refer to ‘Op-
tions Page’).
Entry Time - This parameter determines the duration (expressed in minutes) of
the Audible signal which will be generated when a ‘Delayed’ Zone of an Armed
Partition is violated. The Entry Time will be signalled by: