53
®®
Section 3 - Programming from PC
Monostable Times
This section describes how to set the ON and OFF Times of Monostable Out-
puts. Accepted values: 0 through 250 seconds.
To used this function, click on "Monostable" check-box.
The ON Time determines the time an Output will remain active.
The OFF Time determines the time an Output will remain in ‘forced’
standby status after expiry of its programmed ON Time.
An Output will hold ‘forced’ standby status (even after its programmed OFF
Time) until the event which generated its activation clears.
Signals
NOTE: The ‘Restoral’ conditions described in this section refer to ‘NON-
Monostable’ Outputs. Under normal circumstances, an Output will restore to
standby when its programmed ON Time expires (refer to ‘Monostable’ and
the respective Table)
NOTE: The text in brackets appears on the Installer Menu.
z Away (Away Arm) - The Output will activate when at least one of its Parti-
tions arms in Away mode.
z Partition Disarmed (Disarmed) - The Output will activate when one of its
Partitions disarms.
z Trouble (Warning) - The Output will activate when a Trouble event occurs
(refer to the ‘Events Page’ section), with the exception of the ‘Telephone
Line Trouble’. The Output will restore automatically when the Trouble clears.
This signal is for Non-Monostable Outputs only.
z Alarm Memory (AlarmMem) - The Output will activate when Alarms are
present in the memory. The Output will restore when the memory resets (via
a ‘Clear Alarm Memory’ command).
z Exit Time (Exit T.) - The Output will activate when the ‘Exit Time’ of its
assigned Partitions is triggered, and will remain active until the ‘Exit Time’
expires.
z Entry Time (Entry T.) - The Output will activate when ‘Entry Time’ of its
assigned Partitions is triggered, and will remain active until the ‘Entry Time’
expires.
z Chime (Chime) - The Output will activate when a ‘Chime’ zone is violated
during disarmed status of one (or more) of its assigned Partitions. The Out-
put will remain active for approximately 1 second. This signal is for
Monostable Outputs only.
z Auto-Arm Timeout (Alert T.) - The Output will activate at the pro-
grammed time, and will remain active during the countdown to automatic
arming.