Electric Actuator ICON2000/ICON2000AD
ADDENDUM A to INSTRUCTION HANDBOOK MAN 618
© Copyright by BIFFI Italia. All right reserved. Page
13
Important
To prevent any water infiltration through the line
cable conduits, be sure the cable glands used have the
minimum degree of protection required by the plant.
To guarantee that the weatherproof and explosion-proof characteristics are
respected, screw the cable gland or the external ATEX certified apparatus
tightly (at least 5 turns) and block them with a thread sealant.
Important
The cables and cable glands MUST be selected
considering the maximum Temperature of the cable
indicated on the label fixed to the base ICON2000
unit.
7.5 Installation in ambient with explosive dusts
Special attention must do to these following points:
before the assembly the joint surfaces must be greased with Aeroshell
grease.
the cable glands must have a protection degree at minimum IP66 or IP68
(15m depth / 90 hours) according to IEC/EN 60529 standard.
periodically verify the quantity of dust deposited on the enclosure and
clean it in the case the quantity becoming more than 5 mm.