EasyManua.ls Logo

BIFFI ICON 2000 - Lithium Battery Change; Special Maintenance

Default Icon
292 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 618/3
92
© Copyright by BIFFI Italia. All rights reserved.
“ICON2000”
instruction and operating manual
Section 618/3 chapt. M
2. Special maintenance
In case actuator failure, please refer to Section 618/3 chapter N for possible causes.
Spare parts can be required to BIFFI: please refer to the individual item number shown in
Section 618/4.
Note: Special maintenance is also recommended when, during operations, the actuator
generates an excessive noise.
3. Lithium battery change
- Isolate the main supply to the actuator and all other control voltages.
Warning: If the actuator is located in a hazardous area a “hot work”
permit must be obtained unless the actuator can be moved
to a non-hazardous area.
- Open the terminal boards cover.
- Disconnect two wires (+) (-) from the main board.
- Bring the cover to a safe area. When in a safe area:
• Remove the label.