10.2.5 Maintenance Commands
Slot 4, Index 0, length 1 byte: maintenance information (Only Write).
Byte
Name
Dim
Range
EU
0
Maintenance command
1 byte
bit0 =1
bit1 =1
Clear Recent Data Log
Set Torque Reference
Slot 4, Index 1, length 4 byte: maintenance information (Read and Write).
Byte
Name
Dim
Range
EU
0-3
Next Maintenance Date
4 byte
dd-mm-20-yy
BCDformat
Slot 4, Index 2, length 4 byte: maintenance information (Read and Write)..
Byte
Name
Dim
Range
EU
0-3
Last Maintenance Date
4 byte
dd-mm-20-yy
BCDformat
Slot 4, Index 3, length 4 byte: maintenance information (Read and Write)..
Byte
Name
Dim
Range
EU
0-3
Startup Date
4 byte
dd-mm-20-yy
BCDformat
Slot 4, Index 4, length 8 byte: Date and Time (Only Write)
Byte
Name
Dim
Range
EU
0-3
Current Date
4 bytes
dd-mm-20-yy
BCD format
4-7
Current Time
4 bytes
00-hh-mm-ss
BCD format