Electric Actuator ICON2000/ICON2000AD
ADDENDUM D to INSTRUCTION HANDBOOK MAN 618
© Copyright by BIFFI Italia. All right reserved. Page
6
2.1 Marking
Template of the label for ICON2000/ICON2000AD
IECEx INE XX.ZZZZ = IECEx REFERENCE CERTIFICATE (CoC)
XX ATEX ZZZZ = ATEX REFERENCE CERTIFICATE
0080 = Notified body for ATEX quality assurance (INERIS)
II = Group II (surface industries)
2 = Category 2 apparatus
G = Explosive atmospheres caused by gas, mists or vapors
D = Explosive atmospheres caused by gas dusts
IP66/68 = Degree of protection
Hazardous zone Categories according to 94/9/CE
Directive
Gas, mists or vapours Zone 0 1G
Gas, mists or vapours Zone 1 2G or 1G
Gas, mists or vapours Zone 2 3G or 2G or 1G
Dust Zone 20 1D
Dust Zone 21 2D or 1D
Dust Zone 22 3D or 2D or 1D
Equipment Protection Level (EPL). EN 60079-14
Explosive Atmosphere
Zone
EPL
Gas
0
Ga
1
Ga or Gb
2
Ga or Gb or Gc
Dust
20
Da
21
Da or Db
22
Da or Db or Dc
3 Applicable Directives, general Standards and Norms
2006/42//EC Machinery Directive.