EasyManua.ls Logo

BIFFI ICON 2000 - Page 190

Default Icon
292 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electric Actuator ICON2000/ICON2000AD
ADDENDUM E to INSTRUCTION HANDBOOK MAN 618
© Copyright by BIFFI Italia. All right reserved. Page
6
2.1 Marking
Template of the label for ICON2000/ICON2000AD
IECEx INE XX.ZZZZ = IECEx REFERENCE CERTIFICATE (CoC)
XX ATEX ZZZZ = ATEX REFERENCE CERTIFICATE
0080 = Notified body for ATEX quality assurance (INERIS)
II = Group II (surface industries)
2 = Category 2 apparatus
G = Explosive atmospheres caused by gas, mists or vapors
D = Explosive atmospheres caused by gas dusts
IP66/68 = Degree of protection
Hazardous zone Categories according to 94/9/CE
Directive
Gas, mists or vapours Zone 0 1G
Gas, mists or vapours Zone 1 2G or 1G
Gas, mists or vapours Zone 2 3G or 2G or 1G
Dust Zone 20 1D
Dust Zone 21 2D or 1D
Dust Zone 22 3D or 2D or 1D
Equipment Protection Level (EPL). EN 60079-14
Explosive Atmosphere
Zone
EPL
Gas
0
Ga
1
Ga or Gb
2
Ga or Gb or Gc
Dust
20
Da
21
Da or Db

Table of Contents

Related product manuals