Electric Actuator ICON2000/ICON2000AD
ADDENDUM E to INSTRUCTION HANDBOOK MAN 618
© Copyright by BIFFI Italia. All right reserved. Page
14
Reinstall all the screws that go with the dismantled parts and block after
spreading them with a film of molybdenum-based grease. This will keep
screws from sticking and make maintenance future operations easier.
In case the screws need to be changed it is mandatory to assure that the
new screws are of the same dimension and same material as the original
ones as stated in this Manual, or of a better quality.
Replace the weatherproof seals that may have been removed i.e: O-Rings
for the cover.
In particular, be sure the joint surfaces of all enclosures are spread with a
film of Aeroshell grease.
8.3 Repairs
When needed, repair must only be carried out with Manufacturer’s original
spare parts.
Warning
TitThe values of gaps of explosion-proof joints are lower
than the maximum specified on Tables of EN/IEC
60079-1 Standard. In case the maintenance should
require the replacement of any component which forms
part of an explosion-proof joint, only an original spare
provided by BIFFI MUST be used. Direct repair or
reconstruction of the above components are not
permitted without the BIFFI permission. Not
performing this procedure will invalidate the product
safety and contractual guarantee.
Original spare parts must be required to the Manufacturer: to ensure that right
spare is provided, serial number printed on the ICON2000 unit enclosure label
must be specified when spares are ordered.