EasyManua.ls Logo

BIFFI ICON 2000 - Page 278

Default Icon
292 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Icon 2000 v4 Profibus EDD for AMS Manual
A
AA
A
© Copyright by BIFFI Italia. All right reserved 234/Rev.1 Page 12
4.4 Maintenance commands
Into this page are grouped maintenance operations that can be done on the Icon 2000v4 actuator.
All the displayed data can be modified; the data are read from the actuator when the window is opened: a
‘Refresh’ button is present for re-read all the data from the actuator.
Name Description
Next Maintenance Date This is the date of the next scheduled actuator maintenance
Last Maintenance Date This is the date of the last maintenance operation done
Start-up Date This is the date of the actuator start-up
Three maintenance buttons are presents:
• “Clear Recent Data Log” that allows to clear the counters of the recent operation log
• “Set Torque Reference” that allows to set the last torque profile as to be the Reference
• “Set device date and time”
When “Set device date and time” button is selected, a new window is displayed.