UF V (E3) 03/2019 Page 103/116
Chamber size 500 700
Environment-specific data UF V-UL (115 V)
Noise level (mean value) dB (A) 47 47
Energy consumption at -80 °C/ -112 °F, with an
ambient temperature of +25 °C / 77°F; ± 10%
kWh/day 7.9 8.1
Filling weight of refrigerant R290 (propane)
(1
st
stage cooling, GWP 3)
kg 0.15 0.15
Filling weight of refrigerant R170 (ethane)
(2
nd
stage cooling, GWP 6)
kg 0.15 0.15
Environment-specific data UF V UL (208-240 V)
Noise level (mean value) dB (A) 47 47
Energy consumption at -80 °C/ -112 °F, with an
ambient temperature of +25 °C / 77°F; ± 10%
kWh/day 7.9 8.1
Filling weight of refrigerant R290 (propane)
(1
st
stage cooling, GWP 3)
kg 0.15 0.15
Filling weight of refrigerant R170 (ethane)
(2
nd
stage cooling, GWP 6)
kg 0.15 0.15
All technical data is specified for chambers with unloaded standard equipment at an ambient temperature
of +22 °C +/- C / 71.6 °F +/- 5.4 °F and a power supply voltage fluctuation of +/-10. Technical data is
determined in accordance to BINDER Factory Standard Part 2:2015 and DIN 12880:2007.
All indications are average values, typical for chambers produced in series. We reserve the right to
change technical specifications at any time.
27.5 Equipment and options (extract)
To operate the chamber, use only original BINDER accessories or accessories / components
from third-party suppliers authorized by BINDER. The user is responsible for any risk arising
from using unauthorized accessories.
Regular equipment
RD4 microprocessor controller for temperature
Electronic error auto-diagnosis system with zero-voltage relay alarm output
Ethernet interface for computer communication
USB interface
Safety controller
V technology (V = vacuum-isolation-panels)
Powerful, energy-efficient refrigeration system
4 compartments, 2 compartment doors
3 shelves
Two 28 mm access ports
Connection kit for cooling water (UF V with water cooling)
Voltage 230 V
Voltage 115 V or 208 V-240 V
Options / accessories
Stainless steel shelf set, 1 shelf with shelf holders
Door access system, consisting of electromechanical door locking und Electronic access control via
NumPad
Battery-buffered alarm system