SERVSWITCH™ OCTET INSTALLER/USER GUIDE
92
To use History mode:
1. Press Ctrl-F9. The mode will display as History.
2. Press each key to perform the action described in the following table.
3. When finished, press
Ctrl-F10 to exit History mode and return to On-Line mode.
Serial SAM pinouts
The Serial SAM pinouts are provided in the following table.
History Mode Control Keys
History Mode Action
Home Move to the top of the buffer.
End Move to the bottom of the buffer.
Page Up Move up one buffer page.
Page Down Move down one buffer page.
Up Arrow Move up one buffer line.
Down Arrow Move down one buffer line.
CTRL-F
Enters
Configuration mode. The Configuration Screen will
display. Press Ctrl-F9 to return to the previous screen with
History mode enabled or Ctrl-F10 to return to the previous
screen with On-Line mode enabled.
CTRL-F11
Clears the history buffer. If you choose this option, a warning
screen will appear. Press Enter to delete the history buffer or
Esc to cancel the action. The previous screen will redisplay.
Serial SAM Pinouts
DB9-F
Host Signal
Name/Description
Signal Flow SRL Signal Name/Description
1 DCD- Data Carrier Detect Out of SRL DTR - Data Terminal Ready
2 RXD - Receive Data Out of SRL TXD - Transmit Data
3 TXD - Transmit Data In to SRL RXD - Receive Data
4 DTR - Data Terminal Ready In to SRL DSR - Data Set Ready
5 GND - Signal Ground N/A GND - Signal Ground
6 DSR - Data Set Ready Out of SRL DTR - Data Terminal Ready
7 RTS - Request to Send In to SRL CTS - Clear to Send