| | | * Startup Dialog
| | | - Current malfunction or message [Default]
| | | - Trip counter and hour meter
| | | * Auto adjust. daylight-saving time
| | | - off
| | | - on [Default]
| | |
| | +- Controller
| | | |
| | | +- General
| | | | * Door gong
| | | | - off
| | | | - on hall calls [Default]
| | | | - on car and hall calls
| | | | - on car calls
| | | | * Car fan mode
| | | | - automatic and manual [Default]
| | | | - manually only
| | | | * Car light out of zone
| | | | - as on idle
| | | | - always on [Default]
| | | | * Car light on faults
| | | | - always on [Default]
| | | | - as on idle
| | | | * Car light on lift remote off
| | | | - on idle [Default]
| | | | - immediately off
| | | | * Car light reduction
| | | | - off [Default]
| | | | - on
| | | | * Car light on brightness
| | | | 10..100 [100] %
| | | | * Car light off brightness
| | | | off/1..100 [20] %
| | | | * Emergency stop cancels calls
| | | | - off [Default]
| | | | - on
| | | | * After em.stop/SLC enable hall calls by car call or manual door
| | | | - off [Default]
| | | | - on
| | | | * Use "no load" signal for making the Occupied-signal
| | | | - off [Default]
| | | | - on
| | | | * Car calls on chemical operation
| | | | - cancel [Default]
| | | | - process all car calls
| | | | * Landing call on floor closes open/opening car door
| | | | - off [Default]
| | | | - on
| | | | * Calls when activating the cleaning operation
| | | | - cancel [Default]
| | | | - process all car calls
| | | | - process car calls, until cleaning floor
| | | | * On lift allocation, ignore door and motion detector
| | | | - off [Default]
| | | | - on
| | | | * Ignore extra calls on Blue Modus
| | | | - off [Default]
| | | | - on
| | | | * Ignore safety light curtain on Blue Modus
| | | | - off [Default]
| | | | - Blue Modus C (Standby)
| | | | - Blue Modus B (Shut Down)
| | | | * Call acknowledges
| | | | - cancel on stopping [Default]
| | | | - cancel after door opening
| | | | - cancel when door opening
| | | | * Temporary enabled calls use blinking acknowledge
| | | | - off [Default]
| | | | - on
| | | | * Disable temporary enabled calls by entering a call
| | | | - on