3 Product Certifications
EC Type Examination for SMZ04 und BPL02
3.1 General Description
The modules safety circuit SMZ-04 and power operating board BPL-
02 with SMZ may only be operated in elevator controllers together
with the system modules bp115, bp117, bp300, bp302, bp304, bp306
and bp308.
After complying with these conditions the safety module can be
used in the following cases
Electrical safety devices pursuant to TRA 261 and DIN EN 81 part
1 and part 2 No. 14.1.2.3 as substitute for mechanical positive
switches.
Circuits with safety features: time delay operation circuit on
shortened buffer stroke TRA 262.53 and DIN EN 81 part 1 and part
2 no. 12.8
Levelling and adjusting with opened car and landing door TRA
265.1 and DIN EN 81 part 1 and part 2 no. 14.2.1.2.
Docking operation TRA 266.3 and DIN EN 81 part 1 and part 2 no.
14.2.1.5
Recognition of an unintentional movement of the car with open door
pursuant to EN 81-1/-2, section 9.11.7 and 9.13.7
13