7 command and programming buttons (Call / End, Info / Set, Up,
Down, Right, Left, OK)
Functions, intervals and lift processes can be freely adjusted
Controls can be locked with codes.
14 Inputs
24 V DC, opto-decoupled, input current approx. 10 mA
8 Outputs
24 V DC, 24 V DC, opto-decoupled, short circuit resistant, overload
resistant
Output current 280 mA, power 6 W
16 Calls
24 V DC,DC, opto-decoupled, input current approx. 10 mA, output
current 280 mA, power 6 W, short circuit resistant, overload resistant
Calls may also be freely parametrised as additional inputs or outputs.
Relay Outputs (Programmable )
Two relays, contact 230 V AC / normally closed contact
Two relays, contact 230 V AC / normally open contact
Four relays, contact 230 V AC / make-break contact
Doors
Integrated selection of three electronic door drive units
Safety Circuit
For relevelling and doors starting to open during slow down (e.g.
SMZ -04)
Integrated Interfaces
LAN interfaces: Ethernet 10/100 MBit for monitoring-
systems
USB-B interface: PC connection for diagnostics and
software updates
DCP-interface: Interface (RS485) for communication
with frequency inverter via the DCP
protocol
CANopen-interfaces: Interface (CAN high speed) for
communication with all components
according to the CANopen application pro
file CiA-417
USB-A Schnittstelle: Useable for USB modems, USB sticks,
Böpa Bluetooth™ or WiFi stick,
42 Installation Manual System »bp308« – Control System »bp30