EasyManua.ls Logo

Böhnke + Partner bp308 - Page 79

Böhnke + Partner bp308
154 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16. In-built motor protection switch, over-current release, current-op-
erated circuit breaker etc. have been set at factory and have to
be individually adapted to the appliances connected by you while
commissioning the control system .
17. According to the respective operation instructions, the following
wiring instructions are to be followed:
Conductor N (N) to terminal 9 of bp308.
Conductor N (N) to terminal 14 of bp308.
18. According to VDE-rules and TRA 200, the signal voltage (minus
24 V DC) is to be connected to the protective earth conductor
(PE) of the mains supply .
- Terminal 100 (minus 24 V DC) of bp308 is to be connected to
the PE terminal in the control unit, thus avoiding a floating net-
work and making it possible to recognize an earth leakage of the
signal voltage (+24 V DC) at once .
- Transformers are connected to the earth at the secondary side
(e.g. special voltage of brake or valve) thus avoiding a floating
network and making it possible to recognize an earth leakage of
the secondary voltage at once.
19. Terminals 20A and 20C (+24 V DC max. 2.2 A) of bp308 are
monitored with regard to overload and short-circuit. Overload is
signalised by the LCD.
20. Safety circuit and query-unit of bp308 are fused at max. 1 A.
21. Pay attention to the control pulse-diagram. Presentation of the
pulse-lugs is not true to scale. It is just a schematical diagram .
22. Arrangement of the shut-down points in the landing area (landing
level zone) is to be observed precisely.
23. Signals from the pulse-generator and flush-level switches can be
monitored on the LC display in the service-menu, sub-menu well
signals, not only in the travel mode but also in the inspection con-
trol mode or emergency control mode.
24. It is possible to keep the car door closed at the landings during
maintenance and service activities. See service-menu, sub-menu
maintenance, on the LCD.
25. During checks, the car can be driven to the top or bottom landing
by activating the »Call« switch:
Switch up: car travels to top landing,
Switch down: car travels to bottom landing.
81