Zone tamper bypass when DEOL zone is bypassed (0 =
disabled, 1 = enabled)
1603 1
Tamper debounce time (unit: x100s) 1675 – 1678 0003
Area and Company Name Programming
Option Address Default
Area 1 name 2595 – 2615 0
Area 2 name 2616 – 2635 0
Area 3 name 2636 – 2655 0
Area 4 name 2656 – 2675 0
Area 5 name 2676 – 2695 0
Area 6 name 2696 – 2715 0
Area 7 name 2716 – 2735 0
Area 8 name 2736 – 2755 0
Area 9 name 2756 – 2775 0
Area 10 name 2776 – 2795 0
Area 11 name 2796 – 2815 0
Area 12 name 2816 – 2835 0
Area 13 name 2836 – 2855 0
Area 14 name 2856 – 2875 0
Area 15 name 2876 – 2895 0
Area 16 name 2896 – 2915 0
Company Name 2916 – 2951 0
An area or company name may have up to 18 characters. Each character of the area or
company name uses 2 addresses.
How to insert alphabetical characters via address programming
Example: A = 4 1, A = Address 3736 = 4, Address 3737 = 1
A character needs 2 values to provide input to 2 addresses. Determine these values using the
matrix of table below. Every character in this table has a row index and also a column index.
Row index is the first, and column index is the second value for each character.
Example: o = 6 15, k = 6 11
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
2 ! " # $ % & ' ( ) * + - , . /
3 0 1 2 3 4 5 6 7 8 9 : ; < = > ?
4 @ A B C D E F G H I J K L M N O
5 P Q R S T U V W X Y Z [ \ ] ^ _
6 a b c d e f g h i j k l m n o
AMAX 2100 / 3000 / 4000 Address Programming | en 131
Bosch Sicherheitsysteme GmbH Installation Guide 2014.11 | 02 | F.01U.267.112