EasyManua.ls Logo

Bosch AMAX 4000 - Trouble Fault Inquiry

Bosch AMAX 4000
160 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Trouble Fault Inquiry
Fault Inquiry
Faults and tampers can be displayed via the fault analysis function. For more information refer
to System View, page 69.
The following faults and tampers are possible:
Lit number indicators Description of the fault or tamper
First Second Third
1 Accessory module failure
1 1 Network/IP module 1 failure
1 1 1 - 2 Network/IP module 1 - 2 failure
1 2 Output expansion module failure
1 2 1 - 2 Output expansion module 1 – 2 fault
1 3 Input expansion module failure
1 3 1 - 6 Input expansion module 1 - 6 failure
1 4 Printer failure
1 4 1 Module DX4010 missing
1 4 2 Printer missing
1 4 3 Printer fault
1 5 RF receiver failure
1 5 1 RF receiver 1 fault
1 5 2 RF receiver 1 missing
1 5 3 RF receiver 1 jammed
1 6 RF sensor failure
1 6 1 RF sensor missing*
1 6 2 RF sensor fault*
1 7 RF repeater failure
1 7 1 – 8 RF repeater 1 – 8 missing
1 8 RF config failure
1 8 1 Configuration conflict sensors*
1 8 2 Configuration conflict repeaters*
1 8 3 Configuration conflict keyfobs*
2 Power failure
2 1 Panel AC failure
2 2 Panel low battery
10.2
140 en | Troubleshooting AMAX 2100 / 3000 / 4000
2014.11 | 02 | F.01U.267.112 Installation Guide Bosch Sicherheitsysteme GmbH

Table of Contents

Other manuals for Bosch AMAX 4000

Related product manuals