Zone Indication Keypad and Event Log
Zones may be indicated on LED/LCD keypads and in event logs with a number that are
different from the zone number used for programming and hardware input.
One area system
Zones are indicated on LED/LCD keypads according to the zone numbers. When one zone is
disabled the indication number of all following (higher) zone numbers will shift to a value
decreased by one.
Multi area system
Only zones assigned to one area are indicated on an area LED/LCD keypad in order beginning
with 1 and by following the order of zone numbers.
Examples:
AMAX 3000 / 4000:
In a one area or area 1 system keypad the zone number 17 is indicated on a 16 zone LED/LCD
keypad. After disabling zone 16 (or another one in range 1 to 16), zone number 17 is indicated
on the LED/LCD keypad as zone number 16.
AMAX 2100:
In a one area system keypad the zone number 17 is indicated on an 8 zone LED/LCD keypad.
After disabling zone 5, zone number 17 is indicated on the LED/LCD keypad as zone number
5.
The following table shows the area assignment and keypad indication of zones in a multi area
system:
Zone Number
Area Indication keypad area 1 Indication keypad area 1
1 2 1
2 2 2
3 1 1
4 1 2
5 1 3
6 1 4
7 2 3
8 2 4
9 2 5
10 2 6
11 1 5
12 1 6