Exit Programming Mode
without saving
[9] [5] [9] + [#]
Exit Programming Mode with
saving
[9] [6] [0] + [#]
Set Factory Default [9] [6] [1] + [#]
Copy Control Panel Data to
Programming Key
[9] [6] [2] + [#]
Copy Programming Key Data
to Control Panel
[9] [6] [3] + [#]
Display Firmware Version [9] [9] [9] + [#]
* This function can be enabled/disabled.
+ This function can be enabled/disabled individually for every user.
D = Duress User
A = Arming User
B = Basic User
S = Super User
M1 = Master User 1
M2 = Master User 2
IN = Installer
Notice!
The installer commands can be used only when all areas of the system are in disarming status
with no alarm activated and when the installer access is enabled by the user.
Code Length
The length of the codes can be set in a range from 4 to 6 digits.
Code Reporting
The following codes are reported when an alarm occurs:
Installer Report = 0
User 1 - 250 Report = 1 - 250
A-Link Report = 251
Phone arm Report = 252
Single-Button arm / disarm Report = 253
Key switch arm / disarm Report = 254
Code Permissions
Tamper Reset by User
This option defines whether tampers can be reset with a user code. If this option is disabled,
tamper resets can only be performed with the installer code.
7.2.3
7.2.4
7.2.5
48 en | Settings AMAX 2100 / 3000 / 4000