Pulse Count Duration
The pulse code duration defines the period for the zone pulse count feature.
Cross Zone Timer
The cross zone timer defines the period for the cross zone feature.
Zone Function Settings
Overview
Zone function option Description
Force arm / bypass 0 Disabled
1 Force arm
2 Bypass
3 All
Silent alarm / Chime
mode
0 Disabled
1 Silent alarm
2 Chime mode
3 All
Zone pulse count 0 Disabled
1-9 1-9 pulses
Zone lockout 0 Disabled
1 1 times alarm lockout
2 3 times alarm lockout
3 6 times alarm lockout
4 Alarm duration
Zone tamper 0 Disabled
1 Enabled
Zone status report 0 No report required
7.3.2
7.3.3
7.3.4
60 en | Settings AMAX 2100 / 3000 / 4000