Maintenance
!
Caution!
Maintenance
Damage or malfunction of the system is possible if it is not maintained on a regular basis.
It is recommended to test the system once a week.
Make sure to get the system maintained four times a year.
Only qualified installers /service personnel are allowed to maintain this system.
Firmware Upgrade with the ICP-EZRU2 Upgrade Key
Use the ICP-EZRU2 firmware upgrade key (green) to upgrade the firmware of the AMAX panel.
1. Power off the AMAX panel and remove the battery.
2. Unplug the USB cable, if plugged.
3. Connect the firmware upgrade key to the plug on top of the printed circuit board (PCB)
of the AMAX panel. Make sure that the direction of the programming key is consistent
with the direction marked on the PCB.
4. Power up the AMAX panel.
The LED of the firmware upgrade key flickers while the upgrade is sent to the AMAX
panel. This takes about one minute. When upgrade is terminated, the LED blinks slowly.
5. Remove upgrade key.