Output time 0638 – 0640 000
03 Selecting the output event* 0641 – 0642 05
Output parameter 0643 – 0644 00
Output pulse 0645 0
Output time 0646 – 0648 180
04 Selecting the output event* 0649 – 0650 07
Output parameter 0651 – 0652 00
Output pulse 0653 0
Output time 0654 – 0656 180
05 (as an
example for the
following
outputs 06 to
20)
Selecting the output event* 0657 – 0658 00
Output parameter 0659 – 0660 00
Output pulse 0661 0
Output time 0662 – 0664 000
* For an explanation of the output events, refer to , page 71 in chapter Outputs, page 71.
For the outputs 06 to 20 the same options as for output 05 can be programmed with the same
number of addresses for each option:
Selecting the output event: 2 addresses each
Output parameter: 2 addresses each
Output pulse: 1 address each
Output time: 3 addresses each
The default values for outputs 06 to 20 are the same as the default values of output 05.
The following addresses are used for programming the outputs 06 to 20:
Output no.
Address Output no. Address Output no. Address
06 0665 – 0672 11 0705 – 0712 16 0745 – 0752
07 0673 – 0680 12 0713 – 0720 17 0753 – 0760
08 0681 – 0688 13 0721 – 0728 18 0761 – 0768
09 0689 – 0696 14 0729 – 0736 19 0769 – 0776
10 0697 – 0704 15 0737 – 0744 20 0777 – 0784
Notice!
When the zone activating alarm is programmed as a silent alarm, keypad and audible alarm
have no output.
AMAX 2100 / 3000 / 4000 Address Programming | en 133
Bosch Sicherheitsysteme GmbH Installation Guide 2014.11 | 02 | F.01U.267.112