4 Restore all wireless zones to a normal condition and reset the fault. For more
information, refer to RF Devices, page 78.
Supervise:
1. Report the wireless zone fault to configured destination when the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 10 for a detailed description).
2. When the fault is reset, send the restored report to the configured destinations.
P The FAULT indicator is turned off when there is no other system fault.
RF Repeater Failure
1-8 RF Repeater 1-8 Missing
Condition:
No status report is send to the receiver in the RF supervision interval if a wireless module is
enabled.
Restore:
4 Make sure that status reports are sent to the receiver in the RF supervision interval and
reset the fault. For more information, refer to RF Devices, page 78.
Supervise:
1. Report the repeater missing fault to configured destination when the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 10 for a detailed description).
2. When the fault is reset, send the restored report to the configured destinations.
P The FAULT indicator is turned off when there is no other system fault.
RF Config Failure
Configuration Conflict Sensors
Condition:
A wireless zone configuration is in error condition.
Restore:
4 Restore all wireless zones to a normal condition and reset the fault. For more
information, refer to RF Devices, page 78.
Supervise:
Slow flash FAULT indicator (refer to Keypad Indicators, page 10 for a detailed description).
4 Reset the fault.
P The FAULT indicator is turned off when there is no other system fault.
Configuration Conflict Repeaters
Condition:
A repeater configuration is in error condition.
Restore:
4 Restore all repeaters to a normal condition and reset the fault. For more information,
refer to RF Devices, page 78.
Supervise:
Slow flash FAULT indicator (refer to Keypad Indicators, page 10 for a detailed description).
4 Reset the fault.
P The FAULT indicator is turned off when there is no other system fault.
Configuration Conflict Keyfobs
Condition:
A keyfob configuration is in error condition.
Restore:
4 Restore all keyfobs to a normal condition and reset the fault. For more information, refer
to RF Devices, page 78.