Loading...
Pin Code
variations:
1000000
Keypads: 4 8 16
DX 3010: 1 2 2
B 426, or DX 4020,
or DX4020G (only
1):
2
DX2010: 3 6
DX 4010: 1
RF Receiver: 1
RF Repeater: DSRF = 0, Radion = 8
RF Sensors: 32 64
RF Keyfobs: DSRF = 24, Radion = 128
Power:
Power Supply
Type:
EN = A
Transformer: 230V Input/18VAC 20VA Fuse = 500mA 230V Input/18VAC 50VA
Fuse = 1A
AC Input: AC Input Voltage: 195 VAC to 253 VAC
Line Voltage Frequency: 50 Hz
DC Output: max current for all components 1100mA max current for all
components 2000mA
max current for all components Battery 7Ah standby 12h (recharge
Batt 80% in 72h) = 550mA
max current for all components Battery 7Ah standby 36h + 15min
alarm current 500mA (recharge Batt 80% in 72h) = 150mA
max current for all
components battery 18
Ah standby 12h
(recharge Batt 80% in
72h) = 1500mA
max current for all
components Battery
18Ah standby 36h
(recharge Batt 80% in
24h) = 480mA
max current for all
components Battery
18Ah standby 36h +
15min alarm current
1000mA (recharge Batt
80% in 24h) = 400mA
AMAX 2100 / 3000 / 4000 Technical Data | en 155
Bosch Sicherheitsysteme GmbH Installation Guide 2014.11 | 02 | F.01U.267.112