1. Disarm:
– Zone normal - no alarm / no report
– Zone triggered - no alarm / no report
2. AWAY Arm:
– Zone normal - no alarm / no report
– Zone triggered - no alarm / no report
– Zone triggered - during exit time - no alarm / no report
– Zone triggered - during entry time - no alarm / no report
3. STAY Arm: same as AWAY Arm performance.
– This zone is mainly for prevention of arming (to ensure exit/entry door is locked
before arming the system and no alarm occurs when entering the premise through
the entry/exit door).
23 - External Fault
The external fault zone type performs as described below:
1. Disarm:
– Zone normal - no alarm / no report
– Zone triggered - fault / report
2. AWAY Arm:
– Zone normal - no alarm / no report
– Zone triggered - alarm / report
– Zone triggered - during exit time - fault / report
– Zone triggered - during entry time - fault / report
3. STAY Arm: same as AWAY Arm performance
– The restore report will be sent when the zone is restored.
24 - Technical Alarm
The technical alarm zone type performs as described below:
1. Disarm:
– Zone normal - no alarm / no report
– Zone triggered - alarm / report
2. AWAY Arm:
– Zone normal - no alarm / no report
– Zone triggered - alarm / report
– Zone triggered - during exit time - alarm / report
– Zone triggered - during entry time - alarm / report
3. STAY Arm: same as AWAY arm performance.
– A technical zone does not send a restore report until the zone is restored.
25 - Reset
The reset zone type performs as described below:
1. Disarm:
– Zone normal - no alarm / no report
– Zone triggered – performs system reset / no report
2. AWAY Arm:
– Zone normal - no alarm / no report
3. STAY Arm: same as AWAY arm performance
AMAX 2100 / 3000 / 4000
Settings | en 57