31 – 24h Alarm
This output is operated when a 24h alarm occurs. This output works only a 24-hour zone.
The output is reset when the 24h alarm is reset or the output time ends.
32 – 24h Panic Alarm
This output is operated when a 24h panic alarm occurs. This output works only on zone type
10.
The output is reset when the 24h panic alarm is reset or the output time ends.
33 – Medical Alarm
This output is operated when a medical alarm occurs.
The output is reset when the medical alarm is reset or the output time ends.
34 – RF Power Fault
The output is operated in the following cases:
The battery of the RF transmitter is low.
The battery of the RF repeater is low.
An AC power fault of the RF repeater occurs.
The output is reset in the following cases:
The RF power is normal and the system is reset.
The programmed output time ends.
35 – Follow Zone
This output imitates the zone state. The output is operated according to the corresponding
zone.
The output is reset according to the corresponding zone.
36 - Schedule
This output is operated when a schedule is enabled.
The output is reset when the schedule is reset or the output time ends.
Output Mode
Three different output modes are available.
0 - Continuous output
The output is continuous, the level is high.
1 - Pulse output
The output occurs in pulses, the period is 1 second.
2- Continuous inverted output
The output is continuous, the level is low (level is high in idle state). When PO-1 or PO-2 is set
to inverted, supervision is disabled for these outputs.
Output Time
Each output is operated for a specific time and resets at the end of output time.
The actual output time of system audio alarm, system alarm, and follow zone event is related
to the ringing of the alarm siren.
The possible output time value range is 0 – 999 seconds.