Motor power supply
View Identificati
on
Function
A1 For power connection U1 at motor
A2 For power connection V1 at motor
A3 For power connection W1 at motor
For equipment grounding connection at motor
Spring terminal (connector) Unit min. max.
Connection cable
Stranded wire
mm
2
0.5 10.0
AWG 24 8
Stripped length mm 12
Occurring current load and minimum required
connection cross section
A See technical data of device used (I
out
)
Occurring voltage load V See technical data of device used (U
out
)
Short circuit protection A1, A2, A3 against each other and each of them against
ground
Tab. 10-10: Function, pin assignment, properties
Motor cable shield connection
Tab. 10-11: Motor cable shield connection
IndraDrive X Drive Controllers Power Sections XCS1, XMD1,
XMQ1
77/123
Mounting, dismounting and electrical installation
R911392532_Edition 01 Bosch Rexroth AG