7. Enter licenseShow; then copy the command output into a text le named "licenseshow.txt."
switch:admin> licenseshow
S9bddb9SQbTAceeC:
Fabric license
eezeRRySff0fSe:
Remote Switch license
bzbzRcbcSc0c0SY:
Remote Fabric license
dSeR9RcSeeTfSAq:
Extended Fabric license
RyeSzRScycTzfT09:
Entry Fabric license
RyeSzRScycazfT0G:
Trunking license
RyeSzRScycS0fT09:
4 Domain Fabric license
8. Enter supportShow; then copy the command output into a text
le named "spptshow.txt."
NOTE
The supportShow command has a very long output and time for completion. It may last 20 minutes or longer
depending on the size of the SAN.
This le provides a backup of all the information that might be required by Technical Support. The information can be used after
the device is restored to the fabric to verify that no unintentional changes have occurred to the fabric.
switch:admin> supportshow
version: 7.4.0
<output truncated>
switch:admin>
9. Record the cable connections between the chassis and the target device and ports.
10. Run supportSave on the active CP. The information recorded can be very important in case you have
diculties during the
replacement process.
Disconnecting from network and fabric
Complete the following steps to disconnect the chassis from the network.
1. Shut down the device using the sysShutdown command on the active CP.
switch:admin> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y
HA is disabled
Stopping blade 1
Shutting down the blade....
Stopping blade 2
Shutting down the blade....
Stopping blade 8
Shutting down the blade....
Broadcast message from root (pts/1) Tue Jul 18 14:23:06 2008...
The system is going down for system halt NOW !!
DANGER
Disconnect the power cord from all power sources to completely remove power from the device.
2. Power o the chassis by ipping all AC power switches to the o position. (The power supply status LED should turn o.)
3. Remove the power cords from the power supplies and the power outlets.
4. Remove the chassis door.
Chassis removal and replacement
Brocade DCX 8510-8 Backbone Hardware Installation Guide
144 53-1002180-15

Table of Contents

Other manuals for Brocade Communications Systems DCX 8510-8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brocade Communications Systems DCX 8510-8 and is the answer not in the manual?

Brocade Communications Systems DCX 8510-8 Specifications

General IconGeneral
BrandBrocade Communications Systems
ModelDCX 8510-8
CategorySwitch
LanguageEnglish

Related product manuals