2-24
Confidential
The center thermistor of the fuser
unit has not reached the specified
temperature within the specified
time.
6A00 2-37
The center thermistor of the fuser
unit has not reached the specified
temperature within the specified
time.
6B00 2-37
The center thermistor of the fuser
unit detected a temperature higher
than the specified value.
6C00 2-37
After the heat unit was heated
normally, the center thermistor of
the fuser unit detected a
temperature lower than the
specified value.
6D00 2-37
The center thermistor of the fuser
unit detected that the heat unit was
not heated.
6E00 2-37
The center thermistor or the side
thermistor of the fuser unit
detected a temperature error.
6F00 2-37
LED
Press [Go] and
[Cancel]
simultaneously once
Press [Go] and
[Cancel]
simultaneously twice
Type of problem
Error
codes
Refer
to: