2-28
Confidential
Print Unable
08
Turn the power off
and then back on
again.
An error occurred in the internal
temperature sensor.
0800 2-50
Print Unable
09
Turn the power off
and then back on
again.
Detected irregular power supply
for more than 100 times.
0900 2-51
Print Unable
0A
Turn the power off
and then back on
again.
Main PCB detected the fan
failure.
0A02 2-51
Print Unable
0B
Turn the power off
and then back on
again.
An error occurred in the high-
voltage power supply PCB while
operating.
0B01 2-52
An error occurred in the high-
voltage power supply PCB
when the machine was in the
ready state.
0B02 2-52
Print Unable
0C
Turn the power off
and then back on
again.
An error occurred in the density
sensor.
0C00 2-52
Print Unable
0E
Turn the power off
and then back on
again.
An error occurred during the
high-voltage power supply PCB
ID check.
0E00 2-52
Print Unable
10
Turn the power off
and then back on
again.
The registration mark sensor R
is dirty and cannot normally
receive reflected light.
1003 2-53
The registration mark sensor L
is dirty and cannot normally
receive reflected light.
1004 2-53
Print Unable
1D
Turn the power off
and then back on
again.
A communication error occurred
in the LED ASSY (black).
1D01 2-54
A communication error occurred
in the LED ASSY (yellow).
1D02 2-54
A communication error occurred
in the LED ASSY (magenta).
1D03 2-54
A communication error occurred
in the LED ASSY (cyan).
1D04 2-54
Print Unable
1E
Turn the power off
and then back on
again.
Main PCB and LED control PCB
cannot access each other.
1E01 2-54
Cannot read/write in the main
PCB and LED control PCB.
1E02 2-54
Error message
Description
Error
codes
Refer
to:
First line Second line