2-36
Confidential
Drum ! Open the Top
Cover. Pull out the
drum unit and
toner cartridge.
Slide the Green tab
on Drum Unit.
Electric discharge that may be
caused by dirt on the corona
wire of the drum unit was
detected.
6A00 2-66
Open the Top
Cover. Pull out the
drum unit and
toner cartridge.
Slide the Green tab
on Drum Unit.
Electrified terminal or GRID
terminal signal detected that the
black drum was not installed
when the machine was turned
ON.
620A 2-62
Electrified terminal or GRID
terminal signal detected that the
yellow drum was not installed
when the machine was turned
ON.
620B 2-62
Electrified terminal or GRID
terminal signal detected that the
magenta drum was not installed
when the machine was turned
ON.
620C 2-62
Electrified terminal or GRID
terminal signal detected that the
cyan drum was not installed
when the machine was turned
ON.
620D 2-62
Drum Stop Replace the Drum
Unit. Refer to the
instructions in the
carton of the new
drum.
Electric discharge was detected
when the number of the black
drum unit rotations had become
more than twice of the upper
limit.
6B01 2-66
Electric discharge was detected
when the number of the yellow
drum unit rotations had become
more than twice of the upper
limit.
6B02 2-66
Electric discharge was detected
when the number of the
magenta drum unit rotations
had become more than twice of
the upper limit.
6B03 2-66
Electric discharge was detected
when the number of the cyan
drum unit rotations had become
more than twice of the upper
limit.
6B04 2-66
Ignore Data Press Stop[x].
Detected undecodable data
during printing.
Received undecodable PS data.
--- 4.11.1
Undecodable PS data is
received.
Error message
Description
Error
codes
Refer
to:
First line Second line