App. 4-20
Confidential
WSW15 (REDIAL facility setting)
• Selectors 1 through 6: Redial interval and No. of redialings
The machine redials by the number of times set by selectors 3 through 6 at intervals set by
selectors 1 and 2.
• Selector 8: CRP option
If a command error occurs in the machine (calling station), the machine usually waits for
three seconds and then makes a retry three times. This CRP option is a request command
that can be sent from the called station for requesting the calling station to retry the failed
command immediately.
Selector
No.
Function Setting and Specifications
1
2
Redial interval
No. 1 2
00: 5 minutes
01: 1 minute
10: 2 minutes
11: 3 minutes
3
|
6
No. of redialings
No.3456
0000 : 16 times
0001 : 1 times
0010 : 2 times
0011 : 3 times
| |
1111 : 15 times
7
Redialing to the called station on
the other end sending no response
0: Yes 1: No
8 CRP option 0: Disable 1: Enable