WSW48 (USB setup latency)
• Selectors 6 through 8: USB setup latency (Not used.)
These selectors should not be disturbed.
WSW49 (End-of-copying beep and black ink print mode)
ms: millisecond(s)
Selector
No.
Function Setting and Specifications
1
2
Not used.
3
|
5
Number of PCs registrable to each
of TWAIN-enabled applications
over a network
No. 3 4 5
000 :25
001 :50
010 :75
011 :100
100 :125
101 :150
110 :175
111 :200
6
|
8
USB setup latency
(Not used.)
No. 6 7 8
0 0 0 : Default period
0 0 1 : Shorter 1
010 :Longer 1
011 :Longer 2
100 :Longer 3
101 :Longer 4
1 1 0 : Shorter 2
1 1 1 : Shorter 3
Selector
No.
Function Setting and Specifications
1
2
Not used.
3 End-of-copying beep (Not used.) 0: Yes 1: No
4
5
Command flag detection time
No. 4 5
0 0 : 150 ms
0 1 : 350 ms
1 0 : 550 ms
1 1 : 750 ms
6
7
CCD warmup time adjustment
(Not used.)
No. 6 7
00: No adjustment
01: 80%
1 0 : 120%
1 1 : 150%
8 Black ink print mode 0: Disable (default) 1: Enable