App. 4-29
Confidential
WSW24 (TAD setting 2)
sec.: second(s)
• Selectors 1 and 2: Maximum OGM recording time (Not used.)
These selectors specify the allowable maximum recording time for an OGM.
• Selectors 3 and 4: Time length from CML ON to start of pseudo ring backtone transmission
These selectors specify the length of time from CML-ON up to the start of pseudo ring
backtone transmission.
In models with an OGM facility, the settings made by these selectors also apply to the
length of time from CML-ON up to the start of OGM transmission.
• Selectors 5 through 8: Attenuator for playback of ICM/OGM to the line (Not used.)
Setting two or more selectors to "1" produces addition of attenuation assigned to each
selector.
This setting is not limited by selector 8 on WSW23.
Selector
No.
Function Setting and Specifications
1
2
Maximum OGM recording time
(Not used.)
No. 1 2
0 0 : 15 sec.
0 1 : 20 sec.
1 0 : 30 sec.
1 1 : 50 sec.
3
4
Time length from CML ON to start
of pseudo ring backtone
transmission
No. 3 4
0 0 : 4 sec.
0 1 : 3 sec.
1 0 : 2 sec.
1 1 : 1 sec.
5
|
8
Attenuator for playback of ICM/
OGM to the line
(Selectable from the range of
0-15 dB)
(Not used.)
No.5678
0000: 0 dB
0001: 1 dB
0010: 2 dB
| |
1111: 15 dB