EasyManua.ls Logo

Brother MFC5490CN - Command Flag Detection Time; Wsw50

Brother MFC5490CN
439 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
App. 4-53
Confidential
Selectors 4 and 5: Command flag detection time
After receiving a command flag, the machine will wait for the command that should follow
for the time length specified by these selectors.
Selector 8: Black ink print mode
If any color ink runs out, printing is no longer possible by default. Setting this selector to
"1" allows the machine to ignore the ink empty state and print data with black ink only,
resulting in a printout missing color components
.
Note: The assurance mode switch setting made by Selector 3 on AMS04 (triggered with
function code 88 described in Chapter 9, Section 9.4.28) allows the machine to print all
color and black data as a monochrome printer with black ink only.
WSW50 (SDAA settings)
Note: WSW50 is applicable to models equipped with an SDAA circuit.
Selectors 5 and 6: Current control to be applied immediately after connection of the line
FAX models equipped with an SDAA circuit (on which an NTU chip is mounted) might
not be connected to a broad band line such as an ADSL (Asynchronous Digital Subscriber
Line) in a stable condition. If those models fail to connect to such a line, try to change the
current control to be applied immediately after connection of the line by using selectors 5
and 6.
If selectors 5 and 6 are set to "0" and "1," respectively, the SDAA draws more current,
decreasing the period required to terminate the current control. If they are set to "1" and
"0," the SDAA finely controls precision of the termination current against the voltage to
approach nearer to the specified DC curve that specifies the current vs. voltage
characteristics of the network termination. Selecting either control may solve an unstable
connection problem.
Selector
No.
Function Setting and Specifications
1
2
Percentage voltage for interpreting
the external telephone as being
hooked up
(based on the network's standard
voltage)
No. 1 2
00: 50%
01: 80%
10: 30%
1 1 : No detection
3
DC mask curve table to be applied
when the line is connected
0: Apply the initial value specified by local
regulations
1: Apply table DC5 prepared specially
4
AC impedance to be applied when
the line is connected
0: 600 termination
1: ZR termination
5
6
Current control to be applied
immediately after connection of
the line
No. 5 6
00: Standard
0 1 : Increase start-up current for
termination
1 0 : Fine current control for
termination
1 1 : Not used. (equal to "0, 0")
7
8
AC voltage threshold for detection
of ring
No. 7 8
00: 19 V
01: 11 V
10: 25 V
11: 31 V

Table of Contents

Related product manuals