App. 4-23
Confidential
WSW18 (Function setting 3)
sec.: second(s)
Selectors 2 and 3: Detection enabled time for CNG or "no tone"
After the line is connected via the external telephone or by picking up the handset of the
machine, the machine can detect a CNG signal or "no tone" for the time length specified by
these selectors. The setting specified by these selectors becomes effective only when
selector 8 on WSW20 is set to "1."
Selector 6: Registration of station ID
Setting this selector to "0" permits the registration of station ID for Austrian and Czech
models.
Selectors 7 and 8: Tone sound monitoring
These selectors set monitoring specifications of the tone sound inputted from the line.
Selector
No.
Function Setting and Specifications
1
Registration of station IDs of PCs
sharing a FAX machine
0: Permitted 1: Prohibited
2
3
Detection enabled time for CNG or
"no tone"
No. 2 3
0 0 : 40 sec.
0 1 : 0 sec. (No detection)
1 0 : 5 sec.
1 1 : 80 sec.
4
5
Not used.
6 Registration of station ID 0: Permitted 1: Prohibited
7
8
Tone sound monitoring
No. 7 8
0 0 : No monitoring
0 1 : No monitoring
1 0 : Up to phase B at the
calling station only
1 1 : All transmission phases
both at the calling and
called stations