Functions and parameters
Operation and connection sequences
Publication No. Date Valid from serial number T-code
261828-040 2008-08-21 6051502 815, 816
© BT Repair Manual RRE140/160/180/200/250 4 – 41
Event: 16. Sideshift, right
Previous event 3. Basic control criteria.
Action(s) The control for the fork lift [B23] is moved towards the operator, and
input A1-X505:3 is reduced from approximately 2.6 V to approximately
0.6 V at the end position of the control.
Contributing factors Sideshift as an optional function.
Resulting conditions The pump motor is supplied with three-phase voltage from the transis-
tor regulator [T2].
Output A5-X131:37 “OUT.AUX DIRECTION A” remains high.
Output A5-X131:11 “OUT.AUX DIRECTION B” reduces the voltage.
Current flows through the coil [Q9].
Output A5-X131:38 “OUT.TILT/SIDESHIFT/AUX 1” reduces the volt-
age.
Current flows through the coil [Q18].
The piston rod end of the sideshift cylinder is drained to the tank.
Event: 17. Sideshift, left
Previous event 3. Basic control criteria.
Action(s) The control for fork lift [B23] is moved away from the operator, and
input A1-X505:3 increases from approximately 2.6 V to approximately
4.7 V at the end position of the control.
Contributing factors Sideshift as an optional function.
Resulting conditions The pump motor is supplied with three-phase voltage from the transis-
tor regulator [T2].
Output A5-X131:37 “OUT.AUX DIRECTION A” remains high.
Output A5-X131:11 “OUT.AUX DIRECTION B” reduces the voltage.
Current flows through the coil [Q8].
Output A5-X131:38 “OUT.TILT/SIDESHIFT/AUX 1” reduces the volt-
age.
Current flows through the coil [Q18].
The piston rod end of the sideshift cylinder is pressurised.